Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Microbiol Spectr ; : e0525622, 2023 Jun 08.
Article in English | MEDLINE | ID: covidwho-20238742

ABSTRACT

The 50% plaque reduction neutralization assay (PRNT50) has been previously used to assess the neutralization capacity of donor plasma against wild-type and variant of concern (VOC) severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Emerging data suggest that plasma with an anti-SARS-CoV-2 level of ≥2 × 104 binding antibody units/mL (BAU/mL) protects against SARS-CoV-2 Omicron BA.1 infection. Specimens were collected using a cross-sectional random sampling approach. For PRNT50 studies, 63 previously analyzed specimens by PRNT50 versus SARS-CoV-2 wild-type, Alpha, Beta, Gamma, and Delta were analyzed by PRNT50 versus Omicron BA.1. The 63 specimens plus 4,390 specimens (randomly sampled regardless of serological evidence of infection) were also tested using the Abbott SARS-CoV-2 IgG II Quant assay (anti-spike [S]; Abbott, Chicago, IL, USA; Abbott Quant assay). In the vaccinated group, the percentages of specimens with any measurable PRNT50 versus wild-type or VOC were wild type (21/25 [84%]), Alpha (19/25 [76%]), Beta (18/25 [72%]), Gamma (13/25 [52%]), Delta (19/25 [76%]), and Omicron BA.1 (9/25 [36%]). In the unvaccinated group, the percentages of specimens with any measurable PRNT50 versus wild type or VOC were wild-type SARS-CoV-2 (16/39 [41%]), Alpha (16/39 [41%]), Beta (10/39 [26%]), Gamma (9/39 [23%]), Delta (16/39 [41%]), and Omicron BA.1 (0/39) (Fisher's exact tests, vaccinated versus unvaccinated for each variant, P < 0.05). None of the 4,453 specimens tested by the Abbott Quant assay had a binding capacity of ≥2 × 104 BAU/mL. Vaccinated donors were more likely than unvaccinated donors to neutralize Omicron when assessed by a PRNT50 assay. IMPORTANCE SARS-CoV-2 Omicron emergence occurred in Canada during the period from November 2021 to January 2022. This study assessed the ability of donor plasma collected earlier (January to March 2021) to generate any neutralizing capacity against Omicron BA.1 SARS-CoV-2. Vaccinated individuals, regardless of infection status, were more likely to neutralize Omicron BA.1 than unvaccinated individuals. This study then used a semiquantitative binding antibody assay to screen a larger number of specimens (4,453) for individual specimens that might have high-titer neutralizing capacity against Omicron BA.1. None of the 4,453 specimens tested by the semiquantitative SARS-CoV-2 assay had a binding capacity suggestive of a high-titer neutralizing capacity against Omicron BA.1. These data do not imply that Canadians lacked immunity to Omicron BA.1 during the study period. Immunity to SARS-CoV-2 is complex, and there is still no wide consensus on correlation of protection to SARS-CoV-2.

2.
Microbiol Spectr ; 10(5): e0281122, 2022 Oct 26.
Article in English | MEDLINE | ID: covidwho-2038255

ABSTRACT

There is evidence that COVID-19 convalescent plasma may improve outcomes of patients with impaired immune systems; however, more clinical trials are required. Although we have previously used a 50% plaque reduction/neutralization titer (PRNT50) assay to qualify convalescent plasma for clinical trials and virus-like particle (VLP) assays to validate PRNT50 methodologies, these approaches are time-consuming and expensive. Here, we characterized the ability of the Abbott severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG II Quant assay to identify high- and low-titer plasma for wild-type and variant (Alpha, Beta, Gamma, and Delta) SARS-CoV-2 characterized by both VLP assays and PRNT50. Plasma specimens previously tested in wild-type, Alpha, Beta, Gamma, and Delta VLP neutralization assays were selected based on availability. Selected specimens were evaluated by the Abbott SARS-CoV-2 IgG II Quant assay [Abbott anti-Spike (S); Abbott, Chicago, IL], and values in units per milliliter were converted to binding antibody units (BAU) per milliliter. Sixty-three specimens were available for analysis. Abbott SARS-CoV-2 IgG II Quant assay values in BAU per milliliter were significantly different between high- and low-titer specimens for wild-type (Mann-Whitney U = 42, P < 0.0001), Alpha (Mann-Whitney U = 38, P < 0.0001), Beta (Mann-Whitney U = 29, P < 0.0001), Gamma (Mann-Whitney U = 0, P < 0.0001), and Delta (Mann-Whitney U = 42, P < 0.0001). A conservative approach using the highest 95% confidence interval (CI) values from wild-type and variant of concern (VOC) SARS-CoV-2 experiments would identify a potential Abbott SARS-CoV-2 IgG II Quant assay cutoff of ≥7.1 × 103 BAU/mL. IMPORTANCE The United States Food and Drug Administration (FDA) issued an Emergency Use Authorization (EUA) for the use of COVID-19 convalescent plasma (CCP) to treat hospitalized patients with COVID-19 in August 2020. However, by 4 February 2021, the FDA had revised the convalescent plasma EUA. This revision limited the authorization for high-titer COVID-19 convalescent plasma and restricted patient groups to hospitalized patients with COVID-19 early in their disease course or hospitalized patients with impaired humoral immunity. Traditionally our group utilized 50% plaque reduction/neutralization titer (PRNT50) assays to qualify CCP in Canada. Since that time, the Abbott SARS-CoV-2 IgG II Quant assay (Abbott, Chicago IL) was developed for the qualitative and quantitative determination of IgG against the SARS-CoV-2. Here, we characterized the ability of the Abbott SARS-CoV-2 IgG II Quant assay to identify high- and low-titer plasma for wild-type and variant (Alpha, Beta, Gamma, and Delta) SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , Antibodies, Viral , Immunoglobulin G , Antibodies, Neutralizing
4.
Microbiol Spectr ; 10(3): e0113422, 2022 06 29.
Article in English | MEDLINE | ID: covidwho-1874515

ABSTRACT

Our group has previously used laboratory and commercially developed assays to understand the IgG responses to SARS-CoV-2 antigens, including nucleocapsid (N), spike (S), and receptor binding domain (RBD), in Canadian blood donors. In this current study, we analyzed 17,428 available and previously characterized retention samples collected from April 2020 to March 2021. The analysis compared the characteristics of the Abbott SARS-CoV-2 IgG II Quant assay (Abbott anti-spike [S], Abbott, Chicago, IL) against four other IgG assays. The Abbott anti-S assay has a qualitative threshold of 50 AU/mL. The four comparator assays were the Abbott anti-nucleocapsid (N) assay and three commonly used Canadian in-house IgG enzyme-linked immunosorbent assays (ELISAs) recognizing distinct recombinant viral antigens, full-length spike glycoprotein, glycoprotein RBD, and nucleocapsid. The strongest qualitative relationship was between Sinai RBD and the Abbott anti-S assay (kappa, 0.707; standard error [SE] of kappa, 0.018; 95% confidence interval, 0.671 to 0.743). We then scored each previously characterized specimen as positive when two anti-SARS-COV-2 assays identified anti-SARS-CoV-2 IgG in the specimen. Using this composite reference standard approach, the sensitivity of the Abbott anti-S assay was 95.96% (95% confidence interval [CI], 93.27 to 97.63%). The specificity of the Abbott anti-S assay was 99.35% (95% CI, 99.21 to 99.46%). Our study provides context on the use of commonly used SARS-CoV-2 serologies in Canada and identifies how these assays qualitatively compare to newer commercial assays. Our next steps are to assess how well the Abbott anti-S assays quantitatively detect wild-type and SARS-CoV-2 variants of concern. IMPORTANCE We describe the qualitative test characteristics of the Abbott SARS-CoV-2 IgG II Quant assay against four other anti-SARS-CoV-2 IgG assays commonly used in Canada. Although there is no gold standard for identifying anti-SARS-CoV-2 seropositivity, aggregate standards can be used to assess seropositivity. In this study, we used a specimen bank of previously well-characterized specimens collected between April 2020 and March 2021. The Abbott anti-S assay showed the strongest qualitative relationship with a widely used laboratory-developed IgG assay for the SARS-CoV-2 receptor binding domain. Using the composite reference standard approach, we also showed that the Abbott anti-S assay was highly sensitive and specific. As new anti-SARS-CoV-2 assays are developed, it is important to compare their test characteristics against other assays that have been extensively used in prior research.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Blood Donors , COVID-19/diagnosis , Canada , Enzyme-Linked Immunosorbent Assay , Humans , Immunoglobulin G , Sensitivity and Specificity
5.
JCI Insight ; 7(11)2022 06 08.
Article in English | MEDLINE | ID: covidwho-1807768

ABSTRACT

BACKGROUNDLimited information is available on the impact of immunosuppressants on COVID-19 vaccination in patients with immune-mediated inflammatory diseases (IMID).METHODSThis observational cohort study examined the immunogenicity of SARS-CoV-2 mRNA vaccines in adult patients with inflammatory bowel disease, rheumatoid arthritis, ankylosing spondylitis, or psoriatic disease, with or without maintenance immunosuppressive therapies. Ab and T cell responses to SARS-CoV-2, including neutralization against SARS-CoV-2 variants, were determined before and after 1 and 2 vaccine doses.RESULTSWe prospectively followed 150 subjects, 26 healthy controls, 9 patients with IMID on no treatment, 44 on anti-TNF, 16 on anti-TNF with methotrexate/azathioprine (MTX/AZA), 10 on anti-IL-23, 28 on anti-IL-12/23, 9 on anti-IL-17, and 8 on MTX/AZA. Ab and T cell responses to SARS-CoV-2 were detected in all participants, increasing from dose 1 to dose 2 and declining 3 months later, with greater attrition in patients with IMID compared with healthy controls. Ab levels and neutralization efficacy against variants of concern were substantially lower in anti-TNF-treated patients than in healthy controls and were undetectable against Omicron by 3 months after dose 2.CONCLUSIONSOur findings support the need for a third dose of the mRNA vaccine and for continued monitoring of immunity in these patient groups.FUNDINGFunded by a donation from Juan and Stefania Speck and by Canadian Institutes of Health (CIHR)/COVID-Immunity Task Force (CITF) grants VR-1 172711 and VS1-175545 (to THW and ACG), CIHR FDN-143250 (to THW), GA2-177716 (to VC, ACG, and THW), and GA1-177703 (to ACG) and the CIHR rapid response network to SARS-CoV-2 variants, CoVaRR-Net (to ACG).


Subject(s)
COVID-19 Vaccines , COVID-19 , Antibodies, Viral , BNT162 Vaccine , COVID-19/prevention & control , Canada , Humans , SARS-CoV-2 , Tumor Necrosis Factor Inhibitors , Vaccines, Synthetic , mRNA Vaccines
6.
Mucosal Immunol ; 15(5): 799-808, 2022 05.
Article in English | MEDLINE | ID: covidwho-1805590

ABSTRACT

Although SARS-CoV-2 infects the upper respiratory tract, we know little about the amount, type, and kinetics of antibodies (Ab) generated in the oral cavity in response to COVID-19 vaccination. We collected serum and saliva samples from participants receiving two doses of mRNA COVID-19 vaccines and measured the level of anti-SARS-CoV-2 Ab. We detected anti-Spike and anti-Receptor Binding Domain (RBD) IgG and IgA, as well as anti-Spike/RBD associated secretory component in the saliva of most participants after dose 1. Administration of a second dose of mRNA boosted the IgG but not the IgA response, with only 30% of participants remaining positive for IgA at this timepoint. At 6 months post-dose 2, these participants exhibited diminished anti-Spike/RBD IgG levels, although secretory component-associated anti-Spike Ab were more stable. Examining two prospective cohorts we found that participants who experienced breakthrough infections with SARS-CoV-2 variants had lower levels of vaccine-induced serum anti-Spike/RBD IgA at 2-4 weeks post-dose 2 compared to participants who did not experience an infection, whereas IgG levels were comparable between groups. These data suggest that COVID-19 vaccines that elicit a durable IgA response may have utility in preventing infection. Our study finds that a local secretory component-associated IgA response is induced by COVID-19 mRNA vaccination that persists in some, but not all participants. The serum and saliva IgA response modestly correlate at 2-4 weeks post-dose 2. Of note, levels of anti-Spike serum IgA (but not IgG) at this timepoint are lower in participants who subsequently become infected with SARS-CoV-2. As new surges of SARS-CoV-2 variants arise, developing COVID-19 booster shots that provoke high levels of IgA has the potential to reduce person-to-person transmission.


Subject(s)
COVID-19 , Viral Vaccines , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines , Humans , Prospective Studies , RNA, Messenger/genetics , SARS-CoV-2 , Secretory Component , Vaccination
7.
Clin Transl Immunology ; 11(3): e1380, 2022.
Article in English | MEDLINE | ID: covidwho-1750347

ABSTRACT

Objectives: Antibody testing against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been instrumental in detecting previous exposures and analyzing vaccine-elicited immune responses. Here, we describe a scalable solution to detect and quantify SARS-CoV-2 antibodies, discriminate between natural infection- and vaccination-induced responses, and assess antibody-mediated inhibition of the spike-angiotensin converting enzyme 2 (ACE2) interaction. Methods: We developed methods and reagents to detect SARS-CoV-2 antibodies by enzyme-linked immunosorbent assay (ELISA). The main assays focus on the parallel detection of immunoglobulin (Ig)Gs against the spike trimer, its receptor binding domain (RBD) and nucleocapsid (N). We automated a surrogate neutralisation (sn)ELISA that measures inhibition of ACE2-spike or -RBD interactions by antibodies. The assays were calibrated to a World Health Organization reference standard. Results: Our single-point IgG-based ELISAs accurately distinguished non-infected and infected individuals. For seroprevalence assessment (in a non-vaccinated cohort), classifying a sample as positive if antibodies were detected for ≥ 2 of the 3 antigens provided the highest specificity. In vaccinated cohorts, increases in anti-spike and -RBD (but not -N) antibodies are observed. We present detailed protocols for serum/plasma or dried blood spots analysis performed manually and on automated platforms. The snELISA can be performed automatically at single points, increasing its scalability. Conclusions: Measuring antibodies to three viral antigens and identify neutralising antibodies capable of disrupting spike-ACE2 interactions in high-throughput enables large-scale analyses of humoral immune responses to SARS-CoV-2 infection and vaccination. The reagents are available to enable scaling up of standardised serological assays, permitting inter-laboratory data comparison and aggregation.

8.
Microbiol Spectr ; 10(1): e0256321, 2022 02 23.
Article in English | MEDLINE | ID: covidwho-1700249

ABSTRACT

We have previously used composite reference standards and latent class analysis (LCA) to evaluate the performance of laboratory assays in the presence of tarnished gold standards. Here, we apply these techniques to repeated, cross-sectional study of Canadian blood donors, whose sera underwent parallel testing with four separate SARS-CoV-2 antibody assays. We designed a repeated cross-sectional design with random cross-sectional sampling of all available retention samples (n = 1500/month) for a 12 -month period from April 2020 until March 2021. Each sample was evaluated for SARS-CoV-2 IgG antibodies using four assays an Abbott Architect assay targeting the nucleocapsid antigen (Abbott-NP, Abbott, Chicago IL) and three in-house IgG ELISAs recognizing distinct recombinant viral antigens: full-length spike glycoprotein (Spike), spike glycoprotein receptor binding domain (RBD) and nucleocapsid (NP). We used two analytic approaches to estimate SAR-CoV-2 seroprevalence: a composite reference standard and LCA. Using LCA to estimate true seropositivity status based on the results of the four antibody tests, we estimated that seroprevalence increased from 0.8% (95% CI: 0.5-1.4%) in April 2020 to 6.3% (95% CI: 5.1-7.6%) in March 2021. Our study provides further support for the use of LCA in upcoming public health crises, epidemics, and pandemics when a gold standard assay may not be available or identifiable. IMPORTANCE Here, we describe an approach to estimating seroprevalence in a low prevalence setting when multiple assays are available and yet no known gold standard exists. Because serological studies identify cases through both diagnostic testing and surveillance, and otherwise silent, unrecognized infections, serological data can be used to estimate the true infection fatality ratio of a disease. However, seroprevalence studies rely on assays with imperfect sensitivity and specificity. Seroreversion (loss of antibody response) also occurs over time, and with the advent of vaccination, distinction of antibody response resulting from vaccination as opposed to antibody response due to infection has posed an additional challenge. Our approach indicates that seroprevalence on Canadian blood donors by the end of March 2021was less than 10%. Our study supports the use of latent class analysis in upcoming public health crises, epidemics, and pandemics when a gold standard assay may not be available or identifiable.


Subject(s)
Antibodies, Viral/blood , Blood Donors/statistics & numerical data , COVID-19/blood , SARS-CoV-2/immunology , Adult , Aged , COVID-19/epidemiology , COVID-19/virology , Canada/epidemiology , Coronavirus Nucleocapsid Proteins/analysis , Coronavirus Nucleocapsid Proteins/immunology , Cross-Sectional Studies , Enzyme-Linked Immunosorbent Assay , Female , Humans , Male , Middle Aged , SARS-CoV-2/genetics , Seroepidemiologic Studies , Spike Glycoprotein, Coronavirus/analysis , Spike Glycoprotein, Coronavirus/immunology , Young Adult
9.
Microbiol Spectr ; 10(1): e0226221, 2022 02 23.
Article in English | MEDLINE | ID: covidwho-1691401

ABSTRACT

This study attempted to understand the levels of neutralizing titers and the breadth of antibody protection against wild-type and variant severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in Canadian blood donors during the first 3 months of 2021. During this period, it is unlikely that many of the blood donors had received a second dose, since vaccine rollout had not yet ramped up, and less than 2% of the Canadian population had received a second dose of vaccine. A repeated cross-sectional design was used. A random cross-sectional sampling of all available Canadian Blood Services retention samples (n = 1,500/month) was drawn monthly for January, February, and March 2021. A tiered testing approach analyzed 4,500 Canadian blood donor specimens for potential evidence of a signal for anti-spike (anti-S), anti-receptor-binding domain (anti-RBD), and anti-nucleocapsid protein (anti-N). Specimens were stratified based on donor-declared vaccination history and then stratified on the presence or absence of anti-N as follows: (i) "vaccinated plus anti-N" (n = 5), (ii) "vaccinated and no anti-N" (n = 20), (iii) "unvaccinated plus anti-N" (n = 20), and (iv) "unvaccinated and no anti-N" (n = 20). Randomized specimens were then characterized for neutralizing capacity against wild-type as well as SARS-CoV-2 variants of concern (VOCs) (Alpha [B.1.1.7], Beta [B.1.351], Gamma [P.1], and Delta [B.1.617.2]) using S-pseudotyped virus-like particle (VLP) neutralization assays. There was no neutralizing capacity against wild-type and VOC VLPs within the "no vaccine and no anti-N" group. Neutralization of Beta VLPs was less than wild-type VLPs within "vaccinated plus anti-N," "vaccinated and no anti-N", and "unvaccinated plus anti-N" groups. IMPORTANCE In the first 3 months of 2021 as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccination was in the initial stages of a mass rollout, Canadian blood donors had various levels of humoral protection against wild-type and variant of concern (VOC) SARS-CoV-2. Very few Canadians would have received a second dose of a SARS-CoV-2 vaccine. In this study, we identified elevated levels of neutralizing capacity, albeit with reduced neutralization capacity against one or more SARS-CoV-2 strains (wild type and VOCs) in vaccinated blood donors. This broad neutralizing response we present regardless of evidence of natural SARS-CoV-2 infection. Neutralizing capacity against wild type and VOCs varied significantly within the unvaccinated group, with one subset of unvaccinated plasma specimens (unvaccinated and no anti-N) having no measurable wild type- nor variant-neutralizing capacity. The study is important because it indicates that vaccination can be associated with a broad neutralizing antibody capacity of donor plasma against SARS-CoV-2 VOCs.


Subject(s)
Antibodies, Viral/blood , Blood Donors/statistics & numerical data , COVID-19/blood , SARS-CoV-2/immunology , Adolescent , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/blood , COVID-19/prevention & control , COVID-19/virology , COVID-19 Vaccines/administration & dosage , Canada , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Neutralization Tests , SARS-CoV-2/genetics , Vaccination , Young Adult
10.
J Immunol ; 208(2): 429-443, 2022 01 15.
Article in English | MEDLINE | ID: covidwho-1674944

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) induces T cell, B cell, and Ab responses that are detected for several months in recovered individuals. Whether this response resembles a typical respiratory viral infection is a matter of debate. In this study, we followed T cell and Ab responses in 24 mainly nonhospitalized human subjects who had recovered from PCR-confirmed SARS-CoV-2 infection at two time points (median of 45 and 145 d after symptom onset). Ab responses were detected in 95% of subjects, with a strong correlation between plasma and salivary anti-spike (anti-S) and anti-receptor binding domain IgG, as well as a correlation between circulating T follicular helper cells and the SARS-CoV-2-specific IgG response. T cell responses to SARS-CoV-2 peptides were determined using intracellular cytokine staining, activation markers, proliferation, and cytokine secretion. All study subjects had a T cell response to at least one SARS-CoV-2 Ag based on at least one T cell assay. CD4+ responses were largely of the Th1 phenotype, but with a lower ratio of IFN-γ- to IL-2-producing cells and a lower frequency of CD8+:CD4+ T cells than in influenza A virus (IAV)-specific memory responses within the same subjects. Analysis of secreted molecules also revealed a lower ratio of IFN-γ to IL-2 and an altered cytotoxic profile for SARS-CoV-2 S- and nucleocapsid-specific responses compared with IAV-specific responses. These data suggest that the memory T cell phenotype after a single infection with SARS-CoV-2 persists over time, with an altered cytokine and cytotoxicity profile compared with long-term memory to whole IAV within the same subjects.


Subject(s)
Antibody Formation , COVID-19/immunology , Immunity, Cellular , Immunoglobulin G/immunology , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Th1 Cells/immunology , Adult , Aged , Female , Humans , Male , Middle Aged , Time Factors
11.
Sci Adv ; 8(3): eabj9815, 2022 Jan 21.
Article in English | MEDLINE | ID: covidwho-1634773

ABSTRACT

Safe and effective vaccines are needed to end the COVID-19 pandemic. Here, we report the preclinical development of a lipid nanoparticle­formulated SARS-CoV-2 mRNA vaccine, PTX-COVID19-B. PTX-COVID19-B was chosen among three candidates after the initial mouse vaccination results showed that it elicited the strongest neutralizing antibody response against SARS-CoV-2. Further tests in mice and hamsters indicated that PTX-COVID19-B induced robust humoral and cellular immune responses and completely protected the vaccinated animals from SARS-CoV-2 infection in the lung. Studies in hamsters also showed that PTX-COVID19-B protected the upper respiratory tract from SARS-CoV-2 infection. Mouse immune sera elicited by PTX-COVID19-B vaccination were able to neutralize SARS-CoV-2 variants of concern, including the Alpha, Beta, Gamma, and Delta lineages. No adverse effects were induced by PTX-COVID19-B in either mice or hamsters. Based on these results, PTX-COVID19-B was authorized by Health Canada to enter clinical trials in December 2020 with a phase 2 clinical trial ongoing.


Subject(s)
COVID-19 Vaccines/immunology , COVID-19/prevention & control , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Vaccines, Synthetic/immunology , mRNA Vaccines/immunology , Animals , Antibodies, Neutralizing/blood , Antibodies, Viral/blood , CD4 Lymphocyte Count , CD8-Positive T-Lymphocytes/immunology , COVID-19/immunology , COVID-19 Vaccines/adverse effects , Canada , Cell Line , Cricetinae , Drug Evaluation, Preclinical , Female , HEK293 Cells , Humans , Immunity, Cellular/immunology , Immunity, Humoral/immunology , Liposomes/pharmacology , Male , Mice , Mice, Inbred BALB C , Mice, Inbred C57BL , Nanoparticles , Spike Glycoprotein, Coronavirus/genetics , Th1 Cells/immunology
12.
Transfusion ; 62(2): 418-428, 2022 02.
Article in English | MEDLINE | ID: covidwho-1571123

ABSTRACT

BACKGROUND: Randomized clinical trial data show that early plasma transfusion may save lives among trauma patients. Supplying plasma in remote environments is logistically challenging. Freeze-dried plasma (FDP) offers a possible solution. STUDY DESIGN AND METHODS: A Terumo BCT plasma freeze-drying system was evaluated. We compared pooled frozen plasma (FP) units with derived Terumo BCT FDP (TFDP) units and pooled COVID-19 convalescent apheresis fresh-frozen plasma (CC-AFFP) with derived CC-TFDP units. Parameters measured were: coagulation factors (F) II; V; VII; VIII; IX; XI; XIII; fibrinogen; Proteins C (PC) and S (PS); antithrombin (AT); α2 -antiplasmin (α2 AP); ADAMTS13; von Willebrand Factor (vWF); thrombin-antithrombin (TAT); D-dimer; activated complement factors 3 (C3a) and 5 (C5a); pH; osmolality; prothrombin time (PT); and activated partial thromboplastin time (aPTT). Antibodies to SARS-CoV-2 in CC-AFFP and CC-TFDP units were compared by plaque reduction assays and viral protein immunoassays. RESULTS: Most parameters were unchanged in TFDP versus FP or differed ≤15%. Mean aPTT, PT, C3a, and pH were elevated 5.9%, 6.9%, 64%, and 0.28 units, respectively, versus FP. CC-TFDP showed no loss of SARS-CoV-2 neutralization titer versus CC-AFFP and no mean signal loss in most pools by viral protein immunoassays. CONCLUSION: Changes in protein activities or clotting times arising from freeze-drying were <15%. Although C3a levels in TFDP were elevated, they were less than literature values for transfusable plasma. SARS-CoV-2-neutralizing antibody titers and viral protein binding levels were largely unaffected by freeze-drying. In vitro characteristics of TFDP or CC-TFDP were comparable to their originating plasma, making future clinical studies appropriate.


Subject(s)
Blood Component Removal , Blood Component Transfusion , COVID-19 , Freeze Drying , Antithrombins , COVID-19/therapy , Canada , Hemostatics , Humans , Immunization, Passive , Plasma , SARS-CoV-2 , Viral Proteins , COVID-19 Serotherapy
13.
Transfusion ; 62(1): 37-43, 2022 01.
Article in English | MEDLINE | ID: covidwho-1470483

ABSTRACT

BACKGROUND: This pilot study assesses the ability of plasma collected from Canadian blood donors in the first wave of the SARS-CoV-2 pandemic to neutralize later SARS-CoV-2 variants of concern (VOCs). STUDY DESIGN AND METHODS: A repeated cross-sectional design was used, and a random cross-sectional sample of all available Canadian Blood Services retention samples (n = 1500/month) was drawn monthly for April and May of 2020. Qualitative IgG analysis was performed on aliquots of specimens using anti-spike, anti-receptor binding domain, and anti-nucleocapsid protein enzyme-linked immunosorbent assays as well as the Abbott Architect SARS CoV-2 IgG assay (Abbott Laboratories) against the anti-nucleocapsid protein. Selected plasma specimens were then assessed for neutralization against VOCs using pseudotyped lentivirus inhibition assays as well as plaque reduction neutralization test 50% (PRNT50 ). RESULTS: Six specimens with a high neutralizing titer against wild-type SARS-CoV-2 and three specimens with a low neutralizing titer against wild-type SARS-CoV-2 were chosen for further analysis against VOCs. Four of six high neutralizing titer specimens had a reduced neutralizing capacity against beta VOCs by both neutralization methods. Three of six high neutralizing titer specimens had reduced neutralization capacity against gamma VOCs. CONCLUSIONS: This preliminary data can be used as a justification for limiting the use of first wave plasma products in upcoming clinical trials but cannot be used to speculate on general trends in the immunity of Canadian blood donors to SARS-CoV-2.


Subject(s)
Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , Blood Donors , COVID-19 , SARS-CoV-2 , COVID-19/therapy , Canada , Cross-Sectional Studies , Humans , Immunization, Passive , Immunoglobulin G/immunology , Neutralization Tests , Pilot Projects , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus , COVID-19 Serotherapy
14.
PLoS One ; 16(9): e0257743, 2021.
Article in English | MEDLINE | ID: covidwho-1435621

ABSTRACT

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) seroprevalence studies bridge the gap left from case detection, to estimate the true burden of the COVID-19 pandemic. While multiple anti-SARS-CoV-2 immunoassays are available, no gold standard exists. METHODS: This serial cross-sectional study was conducted using plasma samples from 8999 healthy blood donors between April-September 2020. Each sample was tested by four assays: Abbott SARS-Cov-2 IgG assay, targeting nucleocapsid (Abbott-NP) and three in-house IgG ELISA assays (targeting spike glycoprotein, receptor binding domain, and nucleocapsid). Seroprevalence rates were compared using multiple composite reference standards and by a series of Bayesian Latent Class Models. RESULT: We found 13 unique diagnostic phenotypes; only 32 samples (0.4%) were positive by all assays. None of the individual assays resulted in seroprevalence increasing monotonically over time. In contrast, by using the results from all assays, the Bayesian Latent Class Model with informative priors predicted seroprevalence increased from 0.7% (95% credible interval (95% CrI); 0.4, 1.0%) in April/May to 0.7% (95% CrI 0.5, 1.1%) in June/July to 0.9% (95% CrI 0.5, 1.3) in August/September. Assay characteristics varied over time. Overall Spike had the highest sensitivity (93.5% (95% CrI 88.7, 97.3%), while the sensitivity of the Abbott-NP assay waned from 77.3% (95% CrI 58.7, 92.5%) in April/May to 64.4% (95% CrI 45.6, 83.0) by August/September. DISCUSSION: Our results confirmed very low seroprevalence after the first wave in Canada. Given the dynamic nature of this pandemic, Bayesian Latent Class Models can be used to correct for imperfect test characteristics and waning IgG antibody signals.


Subject(s)
COVID-19/immunology , SARS-CoV-2/immunology , Adult , Aged , Antibodies, Viral/immunology , Bayes Theorem , Blood Donors , Canada , Cross-Sectional Studies , Female , Humans , Immunoglobulin G/immunology , Male , Middle Aged , Nucleocapsid/immunology , Pandemics/prevention & control , Sensitivity and Specificity , Seroepidemiologic Studies , Spike Glycoprotein, Coronavirus/immunology , Young Adult
15.
J Immunol ; 206(1): 37-50, 2021 01 01.
Article in English | MEDLINE | ID: covidwho-934539

ABSTRACT

There is a pressing need for an in-depth understanding of immunity to SARS-CoV-2. In this study, we investigated human T cell recall responses to fully glycosylated spike trimer, recombinant N protein, as well as to S, N, M, and E peptide pools in the early convalescent phase and compared them with influenza-specific memory responses from the same donors. All subjects showed SARS-CoV-2-specific T cell responses to at least one Ag. Both SARS-CoV-2-specific and influenza-specific CD4+ T cell responses were predominantly of the central memory phenotype; however SARS-CoV-2-specific CD4+ T cells exhibited a lower IFN-γ to TNF ratio compared with influenza-specific memory responses from the same donors, independent of disease severity. SARS-CoV-2-specific T cells were less multifunctional than influenza-specific T cells, particularly in severe cases, potentially suggesting exhaustion. Most SARS-CoV-2-convalescent subjects also produced IFN-γ in response to seasonal OC43 S protein. We observed granzyme B+/IFN-γ+, CD4+, and CD8+ proliferative responses to peptide pools in most individuals, with CD4+ T cell responses predominating over CD8+ T cell responses. Peripheral T follicular helper (pTfh) responses to S or N strongly correlated with serum neutralization assays as well as receptor binding domain-specific IgA; however, the frequency of pTfh responses to SARS-CoV-2 was lower than the frequency of pTfh responses to influenza virus. Overall, T cell responses to SARS-CoV-2 are robust; however, CD4+ Th1 responses predominate over CD8+ T cell responses, have a more inflammatory profile, and have a weaker pTfh response than the response to influenza virus within the same donors, potentially contributing to COVID-19 disease.


Subject(s)
Antigens, Viral/immunology , CD4-Positive T-Lymphocytes/immunology , Inflammation/immunology , Orthomyxoviridae/immunology , SARS-CoV-2/immunology , Adult , Aged , Female , Humans , Male , Middle Aged
16.
Sci Immunol ; 5(52)2020 10 08.
Article in English | MEDLINE | ID: covidwho-842548

ABSTRACT

While the antibody response to SARS-CoV-2 has been extensively studied in blood, relatively little is known about the antibody response in saliva and its relationship to systemic antibody levels. Here, we profiled by enzyme-linked immunosorbent assays (ELISAs) IgG, IgA and IgM responses to the SARS-CoV-2 spike protein (full length trimer) and its receptor-binding domain (RBD) in serum and saliva of acute and convalescent patients with laboratory-diagnosed COVID-19 ranging from 3-115 days post-symptom onset (PSO), compared to negative controls. Anti-SARS-CoV-2 antibody responses were readily detected in serum and saliva, with peak IgG levels attained by 16-30 days PSO. Longitudinal analysis revealed that anti-SARS-CoV-2 IgA and IgM antibodies rapidly decayed, while IgG antibodies remained relatively stable up to 105 days PSO in both biofluids. Lastly, IgG, IgM and to a lesser extent IgA responses to spike and RBD in the serum positively correlated with matched saliva samples. This study confirms that serum and saliva IgG antibodies to SARS-CoV-2 are maintained in the majority of COVID-19 patients for at least 3 months PSO. IgG responses in saliva may serve as a surrogate measure of systemic immunity to SARS-CoV-2 based on their correlation with serum IgG responses.


Subject(s)
Antibodies, Viral/blood , Antigens, Viral/immunology , Betacoronavirus/immunology , Coronavirus Infections/immunology , Pneumonia, Viral/immunology , Saliva/immunology , Spike Glycoprotein, Coronavirus/immunology , Adult , COVID-19 , Coronavirus Infections/virology , Cross-Sectional Studies , Enzyme-Linked Immunosorbent Assay , Female , Humans , Immunoglobulin A/blood , Immunoglobulin A/immunology , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunoglobulin M/blood , Immunoglobulin M/immunology , Longitudinal Studies , Male , Middle Aged , Pandemics , Pneumonia, Viral/virology , SARS-CoV-2
17.
JCI Insight ; 5(19)2020 10 02.
Article in English | MEDLINE | ID: covidwho-737501

ABSTRACT

Most of the patients infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) mount a humoral immune response to the virus within a few weeks of infection, but the duration of this response and how it correlates with clinical outcomes has not been completely characterized. Of particular importance is the identification of immune correlates of infection that would support public health decision-making on treatment approaches, vaccination strategies, and convalescent plasma therapy. While ELISA-based assays to detect and quantitate antibodies to SARS-CoV-2 in patient samples have been developed, the detection of neutralizing antibodies typically requires more demanding cell-based viral assays. Here, we present a safe and efficient protein-based assay for the detection of serum and plasma antibodies that block the interaction of the SARS-CoV-2 spike protein receptor binding domain (RBD) with its receptor, angiotensin-converting enzyme 2 (ACE2). The assay serves as a surrogate neutralization assay and is performed on the same platform and in parallel with an ELISA for the detection of antibodies against the RBD, enabling a direct comparison. The results obtained with our assay correlate with those of 2 viral-based assays, a plaque reduction neutralization test (PRNT) that uses live SARS-CoV-2 virus and a spike pseudotyped viral vector-based assay.


Subject(s)
Antibodies, Neutralizing/immunology , Coronavirus Infections/immunology , Coronavirus Infections/therapy , Pneumonia, Viral/immunology , Pneumonia, Viral/therapy , Spike Glycoprotein, Coronavirus/immunology , Antibodies, Viral/blood , Area Under Curve , COVID-19 , Enzyme-Linked Immunosorbent Assay , Humans , Immunization, Passive/methods , Neutralization Tests , Pandemics , Regression Analysis , Sampling Studies , Treatment Outcome , Viral Envelope Proteins/immunology , COVID-19 Serotherapy
SELECTION OF CITATIONS
SEARCH DETAIL